Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.
Universal input usable for resistance thermometer (RTD), thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV)
HART® protocol for converting various input signals to a scalable 4 to 20 mA analog output signal. Operating the transmitter using handheld terminals Field Xpert SFX350/370, field communicator 475 or remotely via PC
FOUNDATION Fieldbus™ ITK 6.1.2
PROFIBUS® PA Profile 3.02
Optional: stainless steel housing for hygienic or Ex d application
Ventajas
High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronics
Backlit display with large measured value, bar graph and status condition indication
Diagnostics information according to NAMUR NE107
International approvals such as FM, CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex nA nL, Ex d and dust ignition-proof); marine approval
SIL certification as per IEC 61508:2010
Galvanic isolation 2 kV (sensor input / current output)
Cómo el perfilado de temperatura aumenta la seguridad de la planta y la calidad del producto en depósitos a granel y silos para almacenamiento de alimentos.
En este white paper se explica cómo pueden utilizarse las sondas de temperatura en la ingeniería de procesos higiénicos. Se detalla la teoría y la práctica, así como ejemplos de aplicación. Más información
Homologación UL Comp FM IS, NI I/1+2/ABCD CSA IS, NI I/1+2/ABCD ATEX II1G Ex ia IIC T6 ATEX II2G Ex d IIC T6 ATEX II3G Ex nA IIC T6 ATEX II3G Ex ic IIC T6 ATEX IECEx II2D Ex tb IIIC Db ATEX II1G Ex ia IIC T6, II2D Ex ia IIIC FM XP, NI, DIP I, II, III/1+2/A-G CSA XP, NI, DIP I, II, III/1+2/A-G FM XP, DIP, IS, NI I, II, III/1+2/A-G CSA XP, DIP, IS, NI I, II, III/1+2/A-G FM+CSA XP, DIP, IS, NI I, II, III/1+2/A-G CSA universal IECEx Ex d IIC T6 Gb IECEx Ex ia, Ex d NEPSI Ex ia IIC T4-T6 NEPSI Ex nA II T4-T6 NEPSI Ex d IIC T4-T6 TIIS Ex ia IIC T4 TIIS Ex ia IIC T6 TIIS Ex d IIC T6 Certificado para aplicaciones marinas solo para protocolo HART SIL2/3 solo para protocolo HART EAC Ex ia IIC T6 Ga EAC Ex d IIC T6 Gb
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Indicador de proceso de 4 hilos con unidad de control como dispositivo de carril DIN con hasta dos entradas de sensor universales y homologación SIL opcional.
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Indicador de proceso de 4 hilos con unidad de control como dispositivo de carril DIN con hasta dos entradas de sensor universales y homologación SIL opcional.
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Utilizamos cookies para mejorar su experiencia de navegación, recopilar estadísticas para optimizar la funcionalidad del sitio y ofrecer publicidad o contenido personalizado.
Al seleccionar «Aceptar todas», autoriza nuestro uso de cookies.
Para obtener más detalles, consulta nuestra política sobre cookies .